Write the question before placing the sensors

A bedroom window that wets overnight, a damp basement, and a humid roofline attic need different comparisons. State the question in one sentence and label the relevant rooms or surfaces. Avoid scattering sensors around the house without deciding what the readings will answer.

The winter-window guide needs bedroom conditions during the wetting period. The basement-after-rim guide needs a consistent foundation-space comparison over weather and operating changes.

Create a room reference location

Use a location representative of ordinary room air, away from direct sun, a supply-air jet, local heat, wet surfaces, and a nearby moisture-control appliance. Record its height and position so it can be restored if moved. Follow the logger manufacturer’s placement and operating instructions.

Do not present a location as perfectly representative of the whole house. A living-room reference, basement reference, and attic location remain separate records. A surface-temperature measurement is another type of evidence; an air logger resting on cold glass is not an appropriate substitute.

Use a second location deliberately

For a localized problem, ask the assessor where a comparison sensor would be useful and what it measures. A labeled “behind curtain” reading can describe that compartment, but it should not be silently substituted for room air. Keep placement safe and accessible without disturbing finishes or insulation.

Do not enter an unreleased foam work area to install a logger. The installation-review guide addresses permitted access. The persistent-odor guide explains why a humidity device cannot establish chemical exposure safety.

Keep a placement register

Swipe horizontally to read all columns on a small screen.

Keep a placement register
Sensor labelLocation and purposeInfluence to note
Bedroom referenceStable room-air comparisonDoor position and heating schedule
Window-area comparisonAssessor-selected local locationCurtain position and proximity to surface
Basement referenceConsistent foundation-space locationWindows, laundry, HVAC, dehumidifier
Roof-space locationAccessible area selected for the questionDucts, vents, roof exposure, access limits
Outdoor comparisonSuitable protected installationWeather exposure and device instructions

Do not place an indoor-only device outdoors or choose an inaccessible roof location just to fill every row. Use only locations needed for the actual investigation.

Check the devices before comparing rooms

Record model, stated accuracy, operating range, and battery or power condition. Let devices stabilize as their instructions require. A side-by-side comparison can reveal disagreement; it does not itself calibrate them or prove which instrument is correct.

If readings differ enough to affect the conclusion, ask about appropriate verification or replacement. Do not “correct” every exported number by an arbitrary offset. Keep the original readings and explain any professionally justified adjustment separately.

Set the clock and record events

Use the same clock and timezone for every logger and event note. Retain temperature units and RH units in the export. Choose a logging interval that captures the event of interest within the device’s capabilities; a long daily average can conceal a short shower or door-opening period.

Download a blank home humidity log CSV. It includes sensor identity, time, temperature, RH, optional dew point, location, and event fields. Blank cells are intentional; the file contains no claimed site measurements.

Compare temperature and moisture carefully

Dew point can help compare air moisture across different temperatures. Two RH percentages from rooms at different temperatures are not a complete moisture comparison. The existing dew-point tool calculates an approximate value from paired air readings.

Keep the original temperature/RH pair alongside any calculated result. Record outdoor conditions from a suitably placed device or identified weather source, and note that a distant station may not describe the air at the house at the exact time.

Hand the reviewer a useful record

Provide the sensor map, raw export, event notes, photographs, and project scope. Mark missing periods and moved sensors rather than joining them into an apparently continuous record. Do not remove inconvenient peaks before sharing the data.

The seasonal humidity-target guide explains what an operating goal needs to specify. The best logger record supports that assessment; it does not independently locate a concealed leak, grade insulation, certify safety, or prove that one repair caused every change.

Questions homeowners ask

Should the logger sit on the wet window sill?
Use a separate room reference and an intentionally labeled local comparison if appropriate. A device on a cold or wet surface does not automatically represent room air.
Do two matching devices prove they are calibrated?
No. Side-by-side agreement or disagreement is useful context, but calibration and verification depend on the instruments and appropriate procedures.
Can RH readings alone compare upstairs and the basement?
Log temperature with RH and consider dew point. Keep placement and operating differences visible in the comparison.

Continue with the next project question

Technical sources and reading

These references support the material and building-science principles discussed above. Check the current product instructions and locally adopted requirements for your specific project. The checklists are planning tools, not site inspection findings.